| '''Recurrent Event Data Analysis Parametric Air-Condition Example'''
| | #REDIRECT[[Example:_Parametric_RDA_-_Air_Condition_Unit]] |
| | |
| The following table gives the failure times of the air-condition unit of an aircraft. The observation ended by the time the last failure occurred. [[Appendix: Weibull References|[3]]]
| |
| <center><math>\begin{matrix}
| |
| \text{50} & \text{329} & \text{811} & \text{991} & \text{1489} \\
| |
| \text{94} & \text{332} & \text{899} & \text{1013} & \text{1512} \\
| |
| \text{196} & \text{347} & \text{945} & \text{1152} & \text{1525} \\
| |
| \text{268} & \text{544} & \text{950} & \text{1362} & \text{1539} \\
| |
| \text{290} & \text{732} & \text{955} & \text{1459} & {} \\
| |
| \end{matrix}</math></center>
| |
| :1. Estimate the GRP model parameters using the Type I virtual age option.
| |
| | |
| :2. Plot the failure number and instantaneous failure intensity vs. time with 90% two-sided confidence bounds.
| |
| | |
| :3. Plot the conditional reliability vs. time with 90% two-sided confidence bounds. The mission start time is 40 and mission time is varying.
| |
| | |
| :4. Using the QCP, calculate the expected failure number and expected instantaneous failure intensity by time 1800.
| |
| | |
| <br>'''Solution'''
| |
| | |
| Enter the data into a parametric RDA folio in Weibull++. Choose '''3''' under Parameters and '''Type I''' under Settings. Keep the default simulation settings.
| |
| | |
| :1. The estimated parameters are <math>\hat{\beta }=1.1976,</math> <math>\hat{\lambda }=4.94E-03,</math> <math>\hat{q}=0.1344</math> . | |
| | |
| :2. The failure number and instantaneous failure intensity are given in the following plots.
| |
| | |
| [[Image:Parametric RDA N(T) plot.png|thumb|center|250px]]
| |
| | |
| [[Image:Parametric RDA Lambda(T) plot.png|thumb|center|250px]]
| |
| | |
| :3. The conditional reliability is plotted below.
| |
| | |
| [[Image:Parametric RDA Cond R(T) plot.png|thumb|center|250px]]
| |
| | |
| :4. Using QCP, the failure number and instantaneous failure intensity are:
| |
| | |
| [[Image:QCP N(T).png|thumb|center|300px]]
| |
| | |
| [[Image:QCP Lambda(T).png|thumb|center|300px]]
| |