Line 7: Line 7:


Block A with Weibull(Beta=1.5, Eta=1000), Block B with Weibull(Beta=1.5, Eta=700), Block C with Weibull(Beta=1.5, Eta=600) and Block D with Weibull(Beta=1.5, Eta=900).
Block A with Weibull(Beta=1.5, Eta=1000), Block B with Weibull(Beta=1.5, Eta=700), Block C with Weibull(Beta=1.5, Eta=600) and Block D with Weibull(Beta=1.5, Eta=900).
The FRED reports for this diagram looks like this:
[[Image:nlytical FRED example 1.png|thumb|center|246px|]]

Revision as of 16:58, 19 March 2012

You can use the analytical results and maintainability/availability simulation results for your BlockSim diagrams and fault trees to generate Failure Reporting, Evaluating and Display (FRED) Reports. These reports provide a graphical demonstration of the reliability and maintainability/availability characteristics of the components in a system and help to identify the components that may require improvement.

Analytical FRED reports illustrate the reliability characteristics of a system’s components in a flexible, color-coded format.

For example, consider a analytical diagram like this:

Anlytical FRED example.png

Block A with Weibull(Beta=1.5, Eta=1000), Block B with Weibull(Beta=1.5, Eta=700), Block C with Weibull(Beta=1.5, Eta=600) and Block D with Weibull(Beta=1.5, Eta=900).

The FRED reports for this diagram looks like this: